T10 PORTABLE TANK INSTRUCTION T10
The general provisions of section 4.2.1 and the requirements of section 6.7.2 shall be met.
Minimum test pressure 4 bar
Minimum shell thickness (reference steel) 6 mm
Pressure-relief provisions A frangible disc preceding a spring-loaded pressure-relief device, or an approved relief device constructed of materials compatible with the load.
Bottom opening provisions Not allowed
Alternatives permitted T14, T19, T20, T22

Special packing provisions:

TP1
The degree of filling prescribed in 4.2.1.9.2 shall not be exceeded.
TP2
The degree of filling prescribed in 4.2.1.9.3 shall not be exceeded.
TP7
Air shall be eliminated from the vapour space by nitrogen or other means.
TP13
Self-contained breathing apparatus shall be provided when this substance is transported, unless no self-contained breathing apparatus, as required by SOLAS regulation II-2/19 (II-2/54), is on board.